Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial

Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial contains 0.2 endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. Furthermore, sample could be added to the vial directly. This means you don’t need to dilute Amebocyte Lysate at first, and could decide how many vials use each time to avoid waste.

 

1. Product Information

Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial Contain 0.2 endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in Vial, you could add sample to the reaction tube directly. This means you don’t need to dilute Amebocyte Lysate at first, and you will decide how many vials use each time to avoid waste. None tube for dilution of CSE is needed. Operation of endotoxin detection by employing our Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial conforms to USP and EP. 

2. Product Parameter

One test per tube

Sensitivities: 0.015, 0.03, 0.06, 0.125, 0.25 EU/ml

Sample requirement: 0.2ml per test.

 

3.Product Feature and Application

Single step endotoxin detection without expensive endotoxin assay instruments. Suitable for end-product endotoxin testing before product released. Product sensitivity standardized with  USP Standard Endotoxin.

Catalog Number Sensitivity (EU/ml)
G020015 0.015
G020030 0.03
G020060 0.06
G020125 0.125
G020250 0.25

 

Storage Condition:

The LAL reagent is stable for more than two years at 2-8℃. Store LAL reagent at 2-8℃ , avoid light. LAL Reagent Water is stable for more than three years at 2-20℃ .

Note:

Lyophilized Amebocyte Lysate (LAL/TAL) reagent manufactured by Bioendo is made from amebocyte lysate from the horseshoe crab (Tachypleus tridentatus).  " For Research Use Only " .

 

For inquiry please kindly email to : lisa@prolabios.com

Related Product

Intended UseBioendo rFC Endotoxin Test Kit (Recombinant Factor C Fluorometric Assay) is intended for use in the In Vitro quantitative detection of gram-negative bacterial endotoxins (Lipopolysaccharid...
Intended UseBioendo rCR Endotoxin Test Kit (Recombinant Cascade Reagents Chromogenic Assay) is intended for use in the In Vitro quantitative detection of gram-negative bacterial endotoxins (Lipopolysa...
Bioendo manufactures Lyophilized Amebocyte Lysate (LAL/TAL) for endotoxin detection since 1978. Lyophilized Amebocyte Lysate (LAL/TAL) Single Test in Ampoule is the is the most economic way ...
1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. For some of our kits, results could be gained within 30 minutes...