Dry Heat Incubator Double Module Double Control or Single Control

Dry bath incubator TAL-M2 is a microprocessor-controlled device, high precision of temperature control, sample preparation parallelism, as an alternative to the traditional water bath device. It is recommended to use in the gel clot TAL endotoxin assay. And it can be widely used in various other application includes the pharmaceutical, chemical, food safety, environment, quality inspection. TAL-M2 includes 2 heating modules, TAL-M4 includes 4 heating modules. TAL- M2A Dry bath incubator Can achieve two independent heating modules, thermostats, unique combo designed to meet the needs of more experimental.

Product features

  1.  LCD display, simple interface.
  2. High heating speed, uniform heating, accurate temperature control, high stability, low energy consumption and no noise.
  3. Built in temperature calibration function, automatic fault detection and buzzer alarm function.
  4. Built in over-temperature protection device, safe and reliable use, prolong the service life of the machine.
  5. Product design, compact and tight, small occupied space, freer and easier.
  6. Various blocks for convenient replacement, cleaning and disinfection.
  7. It Can achieve two independent heating modules, thermostats, unique combo designed to meet the needs of more experimental.

Ordering information

  • TAL-M2 Dry Heat Incubator (Double modules) - TAL-M2
  • TAL-M2 Dry Heat Incubator (Double modules, dual temperature control) - TAL-M2A
  • TAL-M2 Dry Heat Incubator (Four modules) - TAL-M4

Product technical parameters

Catalogue TAL-M2 TAL-M2A TAL-M4
Product name TAL-M2 Dry heat incubator (double   modules) TAL-M2A Dry heat incubator (double modules, dual   temperature control) TAL-M4 Dry heat incubator (four modules)
Temperature range ambient+5℃ ~ 150℃ ambient+5℃ ~ 120℃

Time required

≤ 30min (from 20℃ rise to 150℃) ≤ 30 min (from 20℃rise to 120℃)
Temperature stability @100~150℃ ≤±1℃
Temperature stability @40~100℃ ≤±0.5℃
Temperature uniformity 40℃ 0.3℃
Displayed Precision 0.1℃
Temperature control time 150℃ 120℃
wattage 400W 600W
dimension

260x220x95mm

260x290x95mm

360x220x95mm 

 

For inquiry please kindly email to : lisa@prolabios.com

Related Product

FA (SEM) SERIES Semi-Micro Analytical Balance Recipe database: 99 datas can be stored Automatic internal calibration (one key trigger cal/automatic time-triggered cal) Tare/counting/percentage t...
The mini dry bath heating block is a micro-processor controlled heating block with semiconductor heating technology. It adapts onboard use, smart, light and convenient for movement, suit for any kind ...
Security Bunsen Burner Safe gas use Bench, Field and Laminar Flow use Fully stainless steel body Inclination Turbo flame Safety Control System Multiple accessories Security Bunsen Burner ...
The SAS Super IAQ is a microbiological air sampler especially suited for the Indoor Air Quality. It is based on the same working “impact” principle of the portable “Surface Air ...
One of the simplest and most widely used methods for susceptibility testing, disk diffusion is extremely flexible, offering a wide variety of antibiotics and concentrations which can easily be changed...
Densitometers are designed for measurement of cell suspension's turbidity in the range: DEN-1 0.3–5.0 McFarland units (100×106 –150×107 cells/ml); DEN-1B 0.0...
Sensor-controlled turntable for Petri dishes The touch-free IR-Sensor technology guarantees extremely simple operation with movements of the hand. Flexible Start-Stop functions or the second timer co...
The Rotating Plate Inoculator (RPI) is used to inoculate 90 mm agar plates for AST methods such as MIC Test Strip and antibiotic disks. The rotation speed can be easily adjusted to user preference. Th...
Annealing without Flame! The electrical sterilization system e-Loop is most suitable for the sterilization of inoculation loops, needles and instruments. It is ideal for laboratories and safety cabin...
GlowZone, IR Microincinerator, 230V (LF4.001.000) just needs to be plugged in and will be immediately ready to use, without any warm-up period. Touch-free: ignition by approach. Specifically focused i...